Accuracy of Burkholderia pseudomallei identification using the API 20NE system and a latex agglutination test

Title
Accuracy of Burkholderia pseudomallei identification using the API 20NE system and a latex agglutination test
Authors
Amornchai, P; Chierakul, W; Wuthiekanun, V; Mahakhunkijcharoen, Y; Phetsouvanh, R; Currie, BJ; Newton, PN; Chau, NV; Wongratanacheewin, S; Day, NPJ; Peacock, SJ
Keywords
RAPID IDENTIFICATION; MONOCLONAL-ANTIBODY; PSEUDOMONAS-PSEUDOMALLEI; BLOOD CULTURES; MELIOIDOSIS; THAILANDENSIS; SEPTICEMIA
Issue Date
2007
Publisher
J CLIN MICROBIOL
Citation
J. Clin. Microbiol.;NOV;2007;45;11
Abstract
In an evaluation of the API 20NE for the identification of Burkholderia spp., 792/800 (99%) Burkholderia pseudomallei and 17/19 (89%) B. cepacia isolates were correctly identified but 10 B. mallei and 98 B. thailandensis isolates were not correctly identified. A latex agglutination test was positive for 796/800 (99.5%) B. pseudomallei isolates and negative for 120 other oxidase-positive gram-negative bacilli.
URI
http://hdl.handle.net/11267/2327
ISSN
0095-1137