Accuracy of AccessBio Immunoglobulin M and Total Antibody Rapid Immunochromatographic Assays for the Diagnosis of Acute Scrub Typhus Infection

Title
Accuracy of AccessBio Immunoglobulin M and Total Antibody Rapid Immunochromatographic Assays for the Diagnosis of Acute Scrub Typhus Infection
Authors
Newton, PN; Hampton, CY; Alter-Hall, K; Teerwarakulpana, T; Prakongpan, S; Ruangveerayuth, R; White, NJ; Day, NPJ; Tudino, MB; Mancuso, N; Fernandez, FM
Keywords
POLYMERASE-CHAIN-REACTION; RICKETTSIA-TSUTSUGAMUSHI; ORIENTIA-TSUTSUGAMUSHI; DENGUE; THAILAND; LAOS
Issue Date
2010
Publisher
CLIN VACCINE IMMUNOL
Citation
Clin. Vaccine Immunol.;FEB;2010;17;2
Abstract
Using archived samples, we assessed the diagnostic capacity of a rapid immunochromatographic test (ICT) for the detection of Orientia tsutsugamushi IgM and total antibodies to aid with the diagnosis of acute scrub typhus infection in febrile patients in Laos. The sensitivity and the specificity of the ICT for the detection of IgM were 96.8% (121/125 samples; 95% confidence interval [CI], 92.1 to 99.1%) and 93.3% (98/105 samples; 95% CI, 86.7 to 97.3%), respectively. For the detection of total antibodies, the sensitivity was 97.6% (122/125 samples; 95% CI, 93.1 to 99.5%), but the specificity was much lower, at 71.4% (75/105 samples; 95% CI, 61.8 to 79.8%).
URI
http://hdl.handle.net/11267/2411
ISSN
1556-6811
Appears in Collections:
5.Mahosot Hospital > Journal articles